A high-throughput, multi-protocol industrial automation edge gateway. Stream, monitor, and scale telemetry from Modbus TCP, MELSEC SLMP, Siemens S7, and Omron FINS to MQTT brokers and time-series databases with sub-50ms polling, store-and-forward edge resilience, and node-locked runtime protection.
A robust, non-intrusive architecture that polls factory controllers on local plant LANs and streams structured JSON payloads to cloud brokers without compromising OT air-gapped security.
Direct socket drivers read registers over local industrial Ethernet (no intermediate OPC server required).
Sub-50ms polling loop, byte/word swap, deadband filtering, and encrypted SQLite disk buffer spooling.
Outbound-only encrypted pipeline. Zero inbound open ports on plant firewall; automatic reconnect backoff.
Consume real-time telemetry across enterprise SCADA, analytics engines, ERP/MES databases, and dashboards.
Optimized asynchronous socket loops query dozens of registers in parallel, eliminating the multi-second lag typical of legacy OPC-DA/UA wrapper bridges.
If the factory internet or corporate WAN disconnects, telemetry queues safely to encrypted local SQLite disk storage and backfills automatically upon reconnect.
Gateway runtime is hardened with PyArmor AES-256 bytecode encryption and hardware MAC/UUID node-locking, preventing unauthorized tampering on customer IPCs.
Native drivers written directly in high-performance socket layers without requiring third-party licensing or heavy runtime dependencies.
Define holding registers, SLMP blocks, and Siemens DB tags in clean JSON or YAML schema. The gateway loads configurations dynamically with hot-reload capabilities, meaning tag additions never require stopping plant production lines.
In industrial automation, loss of telemetry during an internet dropout breaks batch traceability records and invalidates ISO/FDA audit trails.
The Techfics Edge Gateway operates an autonomous, transactional local SQLite circular buffer. If connection to the remote MQTT broker drops:
Discover how Techfics deployed air-gapped shop-floor edge nodes, automated 2D QR batch travelers, and PLC telemetry lockouts for Tokyo Stock Exchange-listed precision manufacturer Maruwa (TSE: 5344), achieving 100% batch traceability and sub-15s audit queries.
Practical answers for plant automation engineers, OT leaders, and industrial software architects.
Yes. The gateway can publish to an on-premises MQTT broker (e.g. EMQX or Mosquitto installed on the local plant server) or stream directly to local SQL Server / PostgreSQL databases. Zero external internet connectivity is required.
Standard Modbus transmits 16-bit words. When reading 32-bit floats, manufacturers use varying endianness formats (Big-Endian `AB CD`, Little-Endian `CD AB`, Mid-Big `BA DC`, or Mid-Little `DC BA`). Our configuration schema includes a per-tag `word_swap` and `byte_swap` boolean flag, converting values accurately to standard IEEE-754 floats.
Yes. Modern industrial PLCs (Siemens S7, MELSEC, Modbus Ethernet couplers) support multiple concurrent TCP socket connections (typically 8 to 64 sockets). Techfics Edge Gateway operates on a dedicated TCP connection, co-existing harmoniously with Kepware, Ignition, or existing Wonderware HMIs.
The gateway is lightweight and cross-platform. It runs reliably on industrial DIN-rail IPCs (Advantech, Moxa, Siemens Microbox), Raspberry Pi CM4 industrial carriers, standard Linux VMs (Ubuntu/Debian), or Windows Server environments.
Schedule a 30-minute technical demonstration with our industrial systems engineers. We will review your PLC register addresses and test live telemetry streaming.